Global Water USB Devices Driver Download For Windows

Global Water USB Devices Driver Download For Windows

  1. USB Drivers - For use with the WL16U, FL16U, GL500U-2-1, and GL500-7-2 dataloggers. Save this file in a folder of your choosing then unzip it using an extraction tool such as Winzip. Save this file in a folder of your choosing then unzip it using an extraction tool such as Winzip.
  2. The Microsoft USB Flash Drive Manager will help you backup and restore presentation, pictures, songs and applications from and to USB Flash Drive devices and take them with you. The application can also help you to classify and name USB Flash Drives images (for instance 'My network configuration' or 'The pictures for my grandma') and lets you.
  3. Now the Global Logger USB Device appears in both the Ports and USB Controllers sections, and it has disappeared from the Other Devices section. In the Ports list, the Global Logger USB Device is shown in COM3; use this port setting when connecting to a Global Water USB Data Logger. The drivers are now installed and ready to use.
Datalogger Product DescriptionInstall driver for usb device

Here you will find our product literature. Please use the free text search to look for manuals, certificates, data sheets, tender texts, safety data sheets, flyers and brochures.

Water

The GL500-2-1 Datalogger is the latest addition to Global Water’s line of rugged remote dataloggers. The dataloggers feature two analog channels and one digital channel for recording data, as well as monitoring battery voltage. The datalogger records over 81,000 readings and has four unique recording options: fast (10 samples per second), programmable interval (1 second to multiple years), logarithmic, and exception. Start and stop alarm times can be programmed to synchronize multiple dataloggers, delay sampling until a preset time, or limit the number of recordings during a day. The dataloggers are available for computers with either a RS-232 serial communications port (GL500S-2-1 version) or a USB port (GL500U-2-1 version).

Remote Monitoring
The GL500-2-1 dataloggers can monitor two 4-20mA sensors (0-5 volt inputs are available as a factory option) and features a scalable digital input that accepts switch closure signals from rain gauges or relays, as well as pulses from various external monitoring and control devices. The datalogger provides switched power to the sensors based on the programmable sample interval and sensor warm up time settings. 2-wire and 3-wire sensors can be quickly connected to the datalogger’s internal terminal strip and calibrated via the Global Logger software. The GL500S-2-1 Datalogger Serial Communications version can be accessed through dial-out to a remote modem attached to the serial communication port.

Software
The GL500-2-1 dataloggers include Global Logger II Windows software and PDA software, which allow for easy setup, calibration, upload, and transfer to a spreadsheet program using a laptop, desktop, or PDA. The Global Logger II Windows software has online help files that are easily accessed using drop down menus and links to quickly find the answers to your questions.

Please note: The Global Logger PDA software, included with the datalogger, does not support the Palm operating system.

Dataloggers Specifications

Windows 10 Usb Drivers Download

Download

Global Dataloggers
Memory: Non-volatile flash memory
Power: Voltage: Two 9VDC alkaline batteries standard. 8 VDC Min. to 24.0 VDC Absolute Maximum.
Standby Current: 65uA Typical
Logging Current: 5mA Typical + sensor current
Analog Sensor Inputs: 4-20mA (0-5VDC as factory option)
Resolution: 12-Bit, 4096 Steps
Channels: 2 Input channels + battery voltage monitor
Sensor Warm-up Time: Programmable, 0-15 Sec
Digital Inputs: Switch closure or pulse input
Maximum Input Voltage: 24VDC
Maximum Frequency: 100Hz
Minimum Pulse Width: 2mS
Maximum Count: 65,535 (16-Bit)
Sample Modes: Fixed Interval Programmable from 1 Sec. to >1 Year
High Speed 10 Samples per second
Logarithmic Sample Rate (Approximation)
Exception (Log only on deviation from previous reading)
Storage Capacity: 81,759 Recordings for all inputs plus time stamp
Data Overwrite: Select memory wrap or unwrap (unwrap will stop logging data once memory is full)
Communication Ports:
GL500S-2-1: RS-232 4-pin circular connector
GL500U-2-1: USB Type B
Selectable Baud Rates: 9600, 19200, 28800, 38400, 57600, 115200
Clock: Synchronizes to the time and date of user's computer
Clock Accuracy: 1 minute per month
Operating Temperature: Industrial, -40ºC to +85ºC (Battery may not apply)
Enclosure: PVC (3' x 3' x 3')
Weight: 0.5 lbs

Datalogger Software
Compatible with Microsoft's Windows 98, ME, 2000, NT, and XP
Windows and Excel are trademarks of the Microsoft Corporation
Tabular Display/Printout
Data in standard spreadsheet format (.CSV)
Programmable alarm start and stop times
Field calibration software and help files included

PDA software: CE and Mobile compatible.

Global Water USB Devices Driver Download For Windows

Datalogger Software Information

The Datalogger includes Global Water Datalogger Software, Windows-based software that provides many useful features, such as real-time readout, measurement interval and engineering unit selection, station ID setting, and sensor calibration. The software makes accessing recorded data and setting options easy. Data downloaded from the datalogger can easily be opened in any PC spreadsheet program for analysis and graphic presentation. Globlal Water's Datalogger Software will run on a PC-type laptop or desktop computer running Windows 98 or later. To communicate with the Datalogger, a standard RS232 serial cable for the GL500S-2-1or a USB Type B cable for the GL500U-2-1 is required. Purchase of the datalogger includes the appropriate communication cable (for communication between the datalogger and your computer).

Datalogger Options

GL500U-2-1 Datalogger
USB version for collecting data with most laptop/desktop computers. Features 2 analog channels and 1 pulse channel. Includes two internal 9V batteries, Windows-based Global Water Datalogger Software, and PDA software for the CE and Mobile operating systems.
GL500S-2-1 Datalogger
SERIAL version for collecting data with most PDAs that use the CE and Mobile operating systems. Features 2 analog channels and 1 pulse channel. Includes two internal 9V batteries, Windows-based Global Water Datalogger Software, and PDA software for the CE and Mobile operating systems.
GL450-2-1 Optional Datalogger Enclosure Upgrade
Rugged weather-resistant enclosure for the Datalogger for addtional protection. NOTE: No additional batteries included.
Deluxe PDA Package
Handheld PDA download package for GL500 Dataloggers. Standard PDA can read data from 23 full dataloggers before running out of memory. NOTE: PDAs WILL NOT INTERFACE WITH GLOBAL WATER DATALOGGERS WITHOUT A CUSTOM SERIAL CABLE (Serial cable is included with this package.)
OTHER REMOTE MONITORING INSTRUMENTS
RM100 Remote Radio Telemetry System
GL500-Mod Modem Package
Includes standard telephone modem and modem adapter cable.
GL500-7-2 Multichannel Data Logger
Features 7 analog channels and 2 pulse channels, USB and serial communication port, and includes software and cables. Requires an external 12 VDC power source.
iRIS 220 Wireless Data Logger
Includes 2-Analog (0-5V), 2-Digital Inputs, 2-Digital Outputs
EBI-20-T-Set Temperature Datalogger Kit
Includes EBI-20-T datalogger, Winlog.basic software, EBI-20 interface, and USB cable.
EBI-85 A-OE Temperature Data Logger
MRC 5000 Circular Chart Recorder with Display
FSS-LTS Flow Sampling System
A unique combination of products that makes monitoring, sampling, and recording stormwater or industrial discharge water flows easy.
WQS-STD Water Quality Sampling System
SIT65 Satellite Internet Telemetry
Includes the following parts: transmitter, antenna with 16’ cable, rugged NEMA 4 enclosure, a rechargeable 5 AH gel cell battery, and mounting hardware.